Skip to main content

Besmak

AIR JET SIEVE SHAKER – BCE-315

Effective single sieve for dry powders, fragile samples or material that can’t be wet sieved, Micron air-jet sieve shaker uses 200mm dia. sieve drums, with 2mm to 20µ particle size range. Unit adapts to 75mm diameter electro-formed sieves in 90mm drums for 45µ to 5µ. Timer and vacuum controls allow reproducibility of the results. Filter attachment, micromesh sieve or cyclone collector accessories may be used to recover fines. Includes 200mm cast aluminum sieve drum housing unit, Plexiglas lid, 15W slotted brass air nozzle, 0-15 minute rotary timer switch, 1HP vacuum power system, gauge and 9.5 gal. recoverable capacity, steel filter canister.

  • Power supply: 220V 50 Hz
  • Weight App.: 50 kg

Standards:

  • EN 933-10
Category:

Air Jet Sieve Shaker

The BCE-315 Air Jet Sieve Shaker is designed for efficient single-sieve particle size analysis of dry powders, fragile samples, and materials that cannot be wet sieved. Manufactured in accordance with EN 933-10, the system combines controlled air flow and vacuum technology to deliver accurate, repeatable, and reliable test results.

The unit accommodates 200 mm diameter sieve drums and can also be adapted for 75 mm electro-formed sieves fitted into 90 mm drums, making it suitable for a wide range of fine particle size analyses.


Air Jet Sieve Shaker Features

  • Designed for effective single-sieve analysis of dry powders, fragile samples, and materials that cannot be wet sieved
  • Suitable for particle size analysis of fine materials
  • Compatible with 200 mm diameter sieve drums
  • Particle size range from 2 mm to 20 µm
  • Adapts to 75 mm electro-formed sieves in 90 mm drums for particle sizes from 45 µm to 5 µm
  • Adjustable timer and vacuum controls for repeatable test results
  • Compatible with filter attachment, micromesh sieve, and cyclone collector accessories for recovering fine particles
  • Cast aluminum housing for 200 mm sieve drums
  • Transparent Plexiglas lid for easy observation during testing
  • 15 W slotted brass air nozzle
  • 0–15 minute rotary timer
  • 1 HP vacuum power system
  • Steel filter canister with 9.5 gal recoverable capacity
  • Manufactured in accordance with EN 933-10

Technical Specifications

Specification Details
Product Code BCE-315
Product Name Air Jet Sieve Shaker
Standard EN 933-10
Sieve Drum Diameter 200 mm
Particle Size Range 2 mm to 20 µm
Electro-Formed Sieve Diameter 75 mm
Electro-Formed Particle Size Range 45 µm to 5 µm
Drum Diameter for Electro-Formed Sieves 90 mm
Timer 0–15 minute rotary timer
Air Nozzle 15 W slotted brass air nozzle
Vacuum Power 1 HP
Recoverable Capacity 9.5 gal
Power Supply 220 V, 50 Hz
Approximate Weight 50 kg

Applications

The BCE-315 Air Jet Sieve Shaker is ideal for particle size analysis of:

  • Dry powders
  • Fragile samples
  • Materials unsuitable for wet sieving
  • Fine particulate materials

Its controlled air flow and vacuum system ensure accurate separation of fine particles while minimizing sample loss, making it suitable for laboratories, research facilities, and quality control applications.


EN 933-10 Compliant Air Jet Sieve Shaker

The BCE-315 Air Jet Sieve Shaker is manufactured in accordance with EN 933-10 for precise single-sieve particle size analysis.

The system utilizes 200 mm diameter sieve drums and covers a particle size range from 2 mm to 20 µm. For finer analyses, it can be fitted with 75 mm electro-formed sieves mounted in 90 mm drums, allowing testing of particle sizes from 45 µm to 5 µm.

Integrated timer and vacuum controls provide excellent repeatability, while optional accessories such as filter attachments, micromesh sieves, and cyclone collectors enable efficient recovery of fine particles during testing.


Product Codes and Available Sieves

Product Code Product Description
BCE-315 Air Jet Sieve Shaker
BCE-315/2 45 µm Sieve for Air Jet Sieve Shaker
BCE-315/3 90 µm Sieve for Air Jet Sieve Shaker
BCE-315/4 150 µm Sieve for Air Jet Sieve Shaker
BCE-315/5 200 µm Sieve for Air Jet Sieve Shaker
BCE-315/6 212 µm Sieve for Air Jet Sieve Shaker
BCE-315/7 32 µm Sieve for Air Jet Sieve Shaker
BCE-315/8 38 µm Sieve for Air Jet Sieve Shaker
BCE-315/9 53 µm Sieve for Air Jet Sieve Shaker
BCE-315/10 63 µm Sieve for Air Jet Sieve Shaker
BCE-315/11 75 µm Sieve for Air Jet Sieve Shaker
BCE-315/12 106 µm Sieve for Air Jet Sieve Shaker

Frequently Asked Questions

What is an Air Jet Sieve Shaker used for?

The Air Jet Sieve Shaker is used for accurate single-sieve particle size analysis of dry powders, fragile samples, and materials that cannot be wet sieved.

Which testing standard does the BCE-315 comply with?

The BCE-315 Air Jet Sieve Shaker is manufactured in accordance with EN 933-10.

What particle size range can the Air Jet Sieve Shaker analyze?

The unit analyzes particles ranging from 2 mm to 20 µm using standard 200 mm sieve drums. With electro-formed sieves, it can analyze particle sizes from 45 µm to 5 µm.

Can electro-formed sieves be used?

Yes. The unit is compatible with 75 mm electro-formed sieves mounted in 90 mm drums.

How does the Air Jet Sieve Shaker improve test repeatability?

Integrated timer and vacuum controls provide consistent airflow and testing conditions, ensuring highly repeatable particle size analysis.

Can fine particles be recovered during testing?

Yes. Filter attachments, micromesh sieves, and cyclone collector accessories can be used to recover fine particles efficiently.

What is the power supply requirement?

The Air Jet Sieve Shaker operates on 220 V, 50 Hz.

What is the approximate weight of the machine?

The approximate weight of the BCE-315 Air Jet Sieve Shaker is 50 kg.


Request More Information

For more information about the BCE-315 Air Jet Sieve Shaker, including available sieve sizes, technical specifications, optional accessories, pricing, or quotation requests, please contact the BESMAK technical sales team.